Before You Start
Please read carefully the building eligibility requirement and primary filters before registration.
 
Building eligibility requirement and primary filters
For the purpose of obtaining a representative data set and fair benchmarking among similar facilities, primary filters are applied for the four building groups, namely commercial office buildings in Singapore and Malaysia, hotels in Singapore and industrial flatted factories in Singapore. The lists of primary filters are shown below. For buildings that cannot meet these requirements, meaningful or accurate benchmarking results may not be obtained.
 

Table 1. Primary filters for commercial office building
Parameters Abbreviation Filtering Criteria
Building location LOC Singapore
Principal building activity PBA Commercial office buildings
Type of main HVAC HVAC Central air conditioning
Building age BA ≤ 25 years
Gross floor area (excluding carpark area) GFA ≥ 2000 m2
Vacancy rate of gross lettable area FLVCR ≤ 30% during last 12 months
Occupant density PD 3 to 10 m2 of gross lettable area per person
Weekly operating hours OH ≥ 44 and ≤ 75 hours/week
Design Efficiency GLA/GFA > 60%
% of air conditioned area ACA/GFA > 60%
% of common area CA/GFA > 0%
% of retail area RETA/GFA ≤ 10%. If > 10%, correction factor will be applied.
% of data centre area DCA/GFA ≤ 0.35%. If > 0.35%, correction factor will be applied
% of carpark area CPA/(GFA+CPA) ≤ 8% above ground, ≤ 5% below ground, otherwise correction factor will be applied

Table 2. Primary filters for Malaysia commercial office building
Parameters Abbreviation Filtering Criteria
Building location LOC Kuala Lumpur, Malaysia
Principal building activity TB Commercial office buildings
Building age BA ≤ 25 years
Gross floor area (excluding carpark area) GFA ≥ 1000 m2
Vacancy rate of gross lettable area FLVCR ≤ 30% during last 12 months
Occupant density PD 3 to 10 m2 of gross lettable area per person
Weekly operating hours OH ≥ 44 and ≤ 75 hours/week
Design Efficiency GLA/GFA > 60%
% of air conditioned area ACA/GFA > 60%
% of common area CA/GFA > 0%
% of retail area RETA/GFA ≤ 10%. If > 10%, correction factor will be applied.
% of data centre area DCA/GFA ≤ 0.35%. If > 0.35%, correction factor will be applied
% of carpark area CPA/(GFA+CPA) ≤ 8% above ground, ≤ 5% below ground, otherwise correction factor will be applied

Table 2. Primary filters for commercial hotel building
Parameters Abbreviation Filtering Criteria
Building location LOC Singapore
Hotel Rating STAR 3 , 4 or 5 Star
Principal building activity PBA Commercial hotel buildings
Type of main HVAC HVAC Central air conditioning
Gross floor area (using central air-conditioning) GFA ≥ 2000 m2
Number Of Hotel Room ROOM ≤ 200
Occupant Rate OPRATE > 60%
% of primary space (hotel guest rooms) PS/GFA ≥ 40%
% of data centre area DCA/GFA ≤ 2%. If > 2%, correction factor will be applied
Restaurant or other dining facilities DINE Present
Swimming Pool SWIM Present





Table 3. Primary filters for industrial flatted factory
Parameters Abbreviation Filtering Criteria
Building location LOC Singapore
Principal building activity BU Industrial flatted factory building
Ventilation type (common area) NV Naturally ventilated
Building age BA ≤ 39 years
Gross floor area (excluding carpark area) GFA ≥ 9000 m2
Landlord common area LCA ≥ 1000 m2
Floor-to-floor height FH ≥ 3.6m and ≤ 6.0m
Occupancy rate of flatted factory OR ≥ 65% during last 12 months
Typical weekly operating hours of landlord common area OH ≥ 44 and ≤ 84 hours/ week
% area of gloss floor area occupied by 24-hour tenant GFA(24HR) ≤ 20%
% of common area CA/GFA > 10% and < 50%